Appendix A Specifications
A-8
A.1.2 Error Detector
Table A.1.2-1 Data Input
Item
Specifications
Bit Rate
Refer to “bit rate” in Table A.1.1-2.
Number of
Channel *
1
Option 011: 1
Option 012: 2
Option 014: 4
Data format
NRZ, mark ratio 1/2
Amplitude
0.05 to 0.8 Vp-p*
2,
*
3
Coupling method
DC coupling, termination voltage 0 V
Threshold
–85 mV to 85 mV*
4
, 1 mV resolution
Sensitivity
Typ. 10 mVp-p*
3,
*
5
Max. 20 mVp-p*
3,
*
5
Stressed Eye
BER 10
–12
(Guaranteed for the trace specified by the stressed mask)
*
6,
*
7
Stressed Mask
Bit Rate
X1 (UI)
Y1 (mV)
10.315 Gbit/s
0.325
25
4.25 Gbit/s
0.325
25
2.125 Gbit/s
0.325
25
Total Jitter TJ
0.65 UI*
7
Deterministic
Jitter DJ(d-d)
0.45 UI*
7
SJ(p-p)
0.22 UI*
7
Connector
SMA jack
External
attenuator factor
0 to 30 dB*
8
, 1 dB resolution
*1: Each channel has both of the Data Input and
Data
Input
connectors, which are for single-ended or differential input.
*2: Without Option 092:
132.813 Mbit/s to 11.32 Gbit/s
With Option 092:
125 Mbit/s to 12.5 Gbit/s
*3: Pattern: PRBS31, Mark ratio: 1/2, Single-ended, Back-to-back
connection
0 UI
1 UI
Y1
–Y1
X1
1–X1
0 mV
Содержание BERTWave MP2100B
Страница 24: ...xxiv...
Страница 96: ...Chapter 2 Before Use 2 42...
Страница 112: ...Chapter 3 Connecting with DUT 3 16...
Страница 250: ...Chapter 7 Measuring Waveform 7 64 Figure 7 12 1 Marker Display...
Страница 262: ...Chapter 7 Measuring Waveform 7 76...
Страница 276: ...Chapter 8 Operating Optical Interface 8 14...
Страница 304: ...Chapter 9 Performance Test 9 28...
Страница 313: ...10 4 Displaying Software Version 10 9 10 Maintenance 4 Touch Exit and then the software version display screen is closed...
Страница 320: ...Chapter 10 Maintenance 10 16...
Страница 374: ...Appendix E Performance Test Record Form E 10...
Страница 382: ...Index Index 6...