UG-1262
Rev. B | Page 289 of 312
Ensuring No Communication Across WUT Power Boundary When Powering Down
When the CPU has advance knowledge about a power-down, it must either check to confirm that there are no posted writes in the WUT
awaiting execution or cancel all queued and executing posted writes in the WUT. Cancellation is achieved by writing a cancellation key
of 0xA2C5 to the GWY register, which takes immediate effect. These actions maintain the integrity of the always on half of the WUT.
Do not post any further register writes to the WUT until power is lost by the core to ensure that no communication between the CPU
and the WUT occurs. Such communication makes the WUT liable to corruption when the WUT power domains isolation barrier is
subsequently activated.