7.12 Limit Function
7-137
Limit type menu
{SLOPING LINE}
: Connects to the limit value of the next segment break
point with a sloped line.
For the final segment, horizontal lines are drawn to the
largest point of stimulus.
For the display format of polar coordinates, the limit
value is fixed up to the next segment break point.
In this case, the result is the same as flat line.
The slope line segment is displayed with SLIN in the
Limit Table.
{FLAT LINE}
: Horizontal lines are drawn up to the next segment break
point.
The limit value is fixed up to the next segment if the next
segment has different limit value.
For the final segment, horizontal lines are drawn to the
largest point of stimulus.
Flat line segment is displayed with FLIN in the Limit
Table.
{SINGLE POINT}
: The judgement is performed at a single stimulus point.
The upper limit is displayed with on the display, and
the lower limit is displayed with .
The single point segment can be used for the terminal of
flat line or sloping line.
Single point segment is displayed with SPO in the Limit
Table.
{LIMIT COLOR}
: Sets line color.
Color-to-setup number relationship is as follows.
2 ; Red
3 ; Purple
4 ; Green
5 ; Blue
6 ; Yellow
7 ; White
{WAVE COLOR}
: Sets trace data color in Fail section.
The relationship of color-to-setup number is the same as
above {LIMIT COLOR}.
Offset limit menu
{STIMULUS OFFSET}
: Adds/subtracts offset value to/from stimulus value of all
segments.
Input offset value by using ENTRY block.
{AMPLITUDE OFFSET}
: Adds/subtracts offset value to/from amplitude value of
all segments.
Input offset value by using ENTRY block.
{MARKER TO AMP. OFS} : Sets offset value of magnitude value by using the active
marker.
10