R3765/67G Series Network Analyzer Operation Manual
11 SPECIFICATIONS
11-6
Signal purity
Harmonic distortion
20dBc (23°C
±
5°C when maximum output)
Non harmonic spurious
30 dBc (For the maximum output, > 1 MHz offset at 23°C to
±
5°C)
Phase noise
(10kHz off)
85dBc/Hz
(300kHz to 40MHz, 23°C
±
5°C)
85dBc/Hz-20Log (f/40MHz) (40MHz to 8GHz, 23°C
±
5°C)
Sweep function
Sweep type
Linear, logarithmic, program or power sweep
Sweep time
0.15ms/1 point
Measurement point
3, 6, 11, 21, 51, 101, 201, 301, 401, 601, 801, 1201 point
Sweep trigger
Continuous, single, hold or external triggering
Attenuation accuracy
R3765AG/BG/CG, R3767AG/BG/CG
For OPT 10, OPT 10 + OPT 11/12/13/14
Attenuation 20dB
±
4dB (Attenuation=0dB reference, 23
°
C
±
5
°
C)
Attenuation 40dB
±
5dB (Attenuation=0dB reference, 23
°
C
±
5
°
C)
Attenuation 60dB
±
6dB (Attenuation=0dB reference, 23
°
C
±
5
°
C)
(Continued)