4.7 Overview of the Machine Parameters
93
4.7 Overview of the Machine Parameters
4.7.1 "System" group
Globally effective machine parameters, valid for the complete system.
Parameter
MP number
Function and input
Behavior
Access
SW version
CfgAxes
Definition of existing axes of all channels in the system;
Create entries for all axes of the machine. Also for spindles and PLC axes.
axisList
100001
Key names for all axes on the machine
Enter the axes of all channels of the machine, inclu-
ding spindles and PLC axes.
Format:
List [0...20]
Input:
Selection menu for axis key names
from Axes/PhysicalAxes
Examples:
X, Y, Z etc. or X-Axis, Y-Axis
etc.
RESET
LEVEL3
spindleIndices
100002
Key names of all spindles on the machine
The spindle key names you define must be contained
in 'MP_axisList'. The list index of a spindle key defines
the programmable spindle number used by the PLC to
identify the spindle.
Format:
List [0...6]
Input:
Selection menu for spindle
key names from Axes/PhysicalAxes
Examples:
Index 0 for Spindle1,
Index 1 for Spindle2 etc.
RESET
LEVEL3
specCoordSysList
100003
(optional parameter)
Key names of special axes for the kinematics
description
If under
MP_specKinCoordSys
(CfgAxisPropKin) the
value
FixedTransAxis
,
DefPointTrans
or
DefPointRot
is defined for an axis, you need to enter the axis con-
cerned here.
Format:
List [0...20]
Input:
Selection menu for axis key names
from Axes/PhysicalAxes
Examples:
C1, C2 etc.
RESET
LEVEL3
Содержание MILLPWR G2
Страница 1: ...Technical Manual ACU RITE MILLPWRG2 ...
Страница 2: ......
Страница 14: ...14 ACU RITE Technical Manual MILLPWRG2 ...
Страница 40: ...40 ACU RITE Technical Manual MILLPWRG2 ...
Страница 56: ...56 ACU RITE Technical Manual MILLPWRG2 3 10 Dimensions 3 10 1 MILLPWRG2 Weight 8 0 kg Dim Inch mm ...
Страница 58: ...58 ACU RITE Technical Manual MILLPWRG2 3 10 3 USB Hub ...
Страница 60: ...60 ACU RITE Technical Manual MILLPWRG2 TS 220 Adapter cable for TS 120 TS 220 ...
Страница 61: ...3 10 Dimensions 61 SE 640 transmitter receiver unit ...
Страница 62: ...62 ACU RITE Technical Manual MILLPWRG2 SE 540 transmitter receiver unit ...
Страница 63: ...3 10 Dimensions 63 TS 440 TS 640 ...
Страница 64: ...64 ACU RITE Technical Manual MILLPWRG2 ...
Страница 392: ...392 ACU RITE Technical Manual MILLPWRG2 ...
Страница 545: ......