6.12 Diagnosis with the Online Monitor (OLM)
479
typeOfMove Possible states:
NONE = 0: Axis is in IDLE state
AXKEY: Manual direction key
PLCPOS: PLC positioning
LIFTOFF: Lift off at Cycle stop
RESTORE_POS: Return to contour (block scan)
SYNCHRON: Synchronism (only for spindles)
PLCMEASURE: Measuring with PLC axes
SG_POS: Positioning with safety-oriented (SG) package
REVOL_FEED: Feed per revolution
SPINDLE: Command to spindle (M3, M4, M19 etc.)
noLimitSw
During PLC positioning, software limit-switch monitoring can
be switched off (T = switched off).
error
The following errors can occur:
AxisAlreadyActive = 1: Axis is already working and cannot be
given a new command.
PlcposAlreadyActive: Axis is already working and cannot be
given a new command.
KeyposAlreadyActive: Axis is already working and cannot be
given a new command.
OnlyOneAxWithKinem: When the kinematics model is swit-
ched on (M128), the PLC-IPO can give commands to only
one axis at a time.
SweAlreadyActive: Axis is located at software limit switch.
MovementCanceled: Movement was canceled.
TsSwitched: Touch probe has triggered
ErrorPending: Probe error must be cleared first (in the error
window).
NoToolAx: No tool axis.
MinFeed: Too small a feed rate is programmed.
M19_ACTIVE: M19 is active; axis cannot be moved.
NoChannel: Feed-per-revolution command was sent to an
axis without NC channel.
M19WithoutRef: Not used.
ReconfigActive: Do not move any axis while changing para-
meters.
AlreadyMaster: This axis is a master and cannot be a slave
at the same time (synchronism).
AlreadySlave: Only the SYCHRON_OFF command is allo-
wed for a slave spindle.
NoSlave: The SYNCHRON_OFF command was sent to a
non-slave spindle.
Variable
Display
Содержание MILLPWR G2
Страница 1: ...Technical Manual ACU RITE MILLPWRG2 ...
Страница 2: ......
Страница 14: ...14 ACU RITE Technical Manual MILLPWRG2 ...
Страница 40: ...40 ACU RITE Technical Manual MILLPWRG2 ...
Страница 56: ...56 ACU RITE Technical Manual MILLPWRG2 3 10 Dimensions 3 10 1 MILLPWRG2 Weight 8 0 kg Dim Inch mm ...
Страница 58: ...58 ACU RITE Technical Manual MILLPWRG2 3 10 3 USB Hub ...
Страница 60: ...60 ACU RITE Technical Manual MILLPWRG2 TS 220 Adapter cable for TS 120 TS 220 ...
Страница 61: ...3 10 Dimensions 61 SE 640 transmitter receiver unit ...
Страница 62: ...62 ACU RITE Technical Manual MILLPWRG2 SE 540 transmitter receiver unit ...
Страница 63: ...3 10 Dimensions 63 TS 440 TS 640 ...
Страница 64: ...64 ACU RITE Technical Manual MILLPWRG2 ...
Страница 392: ...392 ACU RITE Technical Manual MILLPWRG2 ...
Страница 545: ......