4.7 Overview of the Machine Parameters
127
code
103905
(optional parameter)
Symbolic name or number of the PLC word marker for
the M code
Name of the PLC word marker in which the M code is
transferred to the PLC.
Example:
DG_M_Function_M10
Format:
String
Input:
PLC operand, max. 80 characters
RESET
LEVEL3
data
103906
Symbolic name or number of the PLC word marker
for additional data
Symbolic name or number of the PLC word marker in
which the additional data of the M function is transmit-
ted to the PLC.
The field size determined from the symbol defines up
to how many data can be saved in the programmed
sequence. If an absolute number is given, only one
value is saved. If no value is entered, no data can be
passed to the PLC.
Format:
String
Input:
PLC operand, max. 80 characters
RESET
LEVEL3
revoke
103907
Nummern von M-Funktionen, deren Wirkung mit
der Ausgabe des Strobes aufgehoben werden sol-
len
In the list, enter the numbers of the functions whose
effect will be canceled when this code is output.
Example: Configuration of function M5
Calling function M5 cancels the effect of functions M3
and M4. In this example, you would enter the key
names of the functions M3 and M4.
The parameter is effective for implementing the state
of the function in the status display and during block
scan.
Format:
List [0...10]
Input:
0 to 9 999
RESET
LEVEL3
Parameter
MP number
Function and input
Behavior
Access
SW version
Содержание MILLPWR G2
Страница 1: ...Technical Manual ACU RITE MILLPWRG2 ...
Страница 2: ......
Страница 14: ...14 ACU RITE Technical Manual MILLPWRG2 ...
Страница 40: ...40 ACU RITE Technical Manual MILLPWRG2 ...
Страница 56: ...56 ACU RITE Technical Manual MILLPWRG2 3 10 Dimensions 3 10 1 MILLPWRG2 Weight 8 0 kg Dim Inch mm ...
Страница 58: ...58 ACU RITE Technical Manual MILLPWRG2 3 10 3 USB Hub ...
Страница 60: ...60 ACU RITE Technical Manual MILLPWRG2 TS 220 Adapter cable for TS 120 TS 220 ...
Страница 61: ...3 10 Dimensions 61 SE 640 transmitter receiver unit ...
Страница 62: ...62 ACU RITE Technical Manual MILLPWRG2 SE 540 transmitter receiver unit ...
Страница 63: ...3 10 Dimensions 63 TS 440 TS 640 ...
Страница 64: ...64 ACU RITE Technical Manual MILLPWRG2 ...
Страница 392: ...392 ACU RITE Technical Manual MILLPWRG2 ...
Страница 545: ......