5.12 Reference Marks
311
5.12.3 Defining the Process of Traversing the Reference Marks
The parameter object CfgReferencing is not required for:
Virtual axes (MP_axisMode=Virtual)
You define the process of traversing the reference marks in the following
machine parameters:
In MP_refDirection and MP_refFeedHigh (for rotary encoders also in
MP_refFeedLow) you define the direction and velocity for traversing the ref-
erence marks.
In MP_refAxis you define the sequence of axes for traversing the reference
marks.
In MP_refType you select the type of reference marks for each axis.
MP_refType
Functional sequence for traversing the reference mark
Format:
Selection menu
Selection:
[ Switch, changing Dir ]
For linear axes with speed encoder; reference run with NC start
[ Switch, no changing Dir ]
For linear axes with speed encoder; reference run with NC start
[ without Switch ]
For spindle, rotary table with angle encoder; reference run with
NC start
[ distance coded ]
For distance-coded linear encoders; reference run with NC start
[ distance coded + on the fly ]
For distance-coded linear encoders; reference run with axis-
direction keys or NC start
[ without on the fly ]
For spindle; reference run with M3, M4
[ Endat Encoder ]
For axes with EnDat encoder; reference-mark traverse not nec-
essary
Settings in the configuration editor:
Axes
ParameterSets
Key for parameter set
CfgReferencing
refType
refSwitchActive
refFeedLow
refFeedHigh
refDirection
Содержание MILLPWR G2
Страница 1: ...Technical Manual ACU RITE MILLPWRG2 ...
Страница 2: ......
Страница 14: ...14 ACU RITE Technical Manual MILLPWRG2 ...
Страница 40: ...40 ACU RITE Technical Manual MILLPWRG2 ...
Страница 56: ...56 ACU RITE Technical Manual MILLPWRG2 3 10 Dimensions 3 10 1 MILLPWRG2 Weight 8 0 kg Dim Inch mm ...
Страница 58: ...58 ACU RITE Technical Manual MILLPWRG2 3 10 3 USB Hub ...
Страница 60: ...60 ACU RITE Technical Manual MILLPWRG2 TS 220 Adapter cable for TS 120 TS 220 ...
Страница 61: ...3 10 Dimensions 61 SE 640 transmitter receiver unit ...
Страница 62: ...62 ACU RITE Technical Manual MILLPWRG2 SE 540 transmitter receiver unit ...
Страница 63: ...3 10 Dimensions 63 TS 440 TS 640 ...
Страница 64: ...64 ACU RITE Technical Manual MILLPWRG2 ...
Страница 392: ...392 ACU RITE Technical Manual MILLPWRG2 ...
Страница 545: ......