6.5 Control Operation in the Machining Channel
411
6.5 Control Operation in the Machining Channel
6.5.1 Channel-Specific Settings
Arc End-Point
Tolerance
The control uses the entered NC data to calculate the deviation of the arc
radius between the beginning and end of the arc:
Enter a tolerance value in MP_circleDeviation. If the entered tolerance is
exceeded, the error message
CIRCLE END POS. INCORRECT
appears.
MP_circleDeviation
Permissible deviation from radius
Format:
Numeric value
Input:
0.00001 to 0.01600 [mm
0.00001 to 0.01600 [mm]
Default: 0.005
Settings in the configuration editor:
NCchannel
ChannelSettings
Key for channel
CfgGeoTolerance
circleDeviation