196
ACU-RITE Technical Manual MILLPWR
G2
angleToleranceHi
201512
(optional parameter)
Tolerance for rotary axes with M128 and rapid
traverse
This value also applies for a feed rate greater
than MP_maxG1Feed.
Format:
Numeric value
Input:
0.0001 to 10.0 [mm]
Default:
0.01 [mm]
Allowed in strobe
LEVEL3
CfgPlcStrobes
Definition of the M, S and T strobes for this channel
mStrobes
201601
List of M strobe descriptions in this channel
Format:
List [0...300]
Input:
Key name of the M function
Selection from
CfgPlcMStrobe
RESET
LEVEL3
sStrobe
201602
List of S strobe descriptions in this channel
Format:
List [0...6]
Input:
Key name of the S function
Selection from
CfgPlcSStrobe
RESET
LEVEL3
tStrobes
201603
List of T strobe descriptions in this channel
Format:
List [0...3]
Input:
Key name of the T function
Selection from
CfgPlcTStrobe
RESET
LEVEL3
aliasStrobes
201604
List of implemented strobes in this channel
Reproduction of control-dependent functions on a
uniform M-function transfer to the PLC program.
Format:
List [0...5]
Input:
Key name of the M function
Selection from
CfgPlcMStrobe
RESET
LEVEL3
unitOfMeasure
201605
(optional parameter)
Symbolic name or number of the PLC marker for
the unit of measure of the NC program
Name of the PLC marker, which informs the PLC
of the unit of measure of the NC program to be
run.
PLC marker = 1: Inches
PLC marker = 0: Metric system
Format:
String
Input:
Max. 24 characters
RESET
LEVEL3
Parameter
MP number
Function and input
Reaction/Access
Содержание MILLPWR G2
Страница 1: ...Technical Manual ACU RITE MILLPWRG2 ...
Страница 2: ......
Страница 14: ...14 ACU RITE Technical Manual MILLPWRG2 ...
Страница 40: ...40 ACU RITE Technical Manual MILLPWRG2 ...
Страница 56: ...56 ACU RITE Technical Manual MILLPWRG2 3 10 Dimensions 3 10 1 MILLPWRG2 Weight 8 0 kg Dim Inch mm ...
Страница 58: ...58 ACU RITE Technical Manual MILLPWRG2 3 10 3 USB Hub ...
Страница 60: ...60 ACU RITE Technical Manual MILLPWRG2 TS 220 Adapter cable for TS 120 TS 220 ...
Страница 61: ...3 10 Dimensions 61 SE 640 transmitter receiver unit ...
Страница 62: ...62 ACU RITE Technical Manual MILLPWRG2 SE 540 transmitter receiver unit ...
Страница 63: ...3 10 Dimensions 63 TS 440 TS 640 ...
Страница 64: ...64 ACU RITE Technical Manual MILLPWRG2 ...
Страница 392: ...392 ACU RITE Technical Manual MILLPWRG2 ...
Страница 545: ......