268
ACU-RITE Technical Manual MILLPWR
G2
Enter the following values for calculating the signal period:
MP_posEncoderDist:
Linear distance for the number of signal periods from
MP_posEncoderIncr
MP_posEncoderIncr:
Number of signal periods for the distance from
MP_posEncoderDist
The control calculates the quotient:
Signal period =
MP_posEncoderDist
Distance for number of signal periods from MP_posEncoderIncr
Format:
Numeric value
Input:
0.000 000 001 to 100 000 [mm] or [°]
Default:
5 [mm] or [°]
MP_posEncoderIncr
Number of signal periods for distance from
MP_posEncoderDist
Format:
Numeric value
Input:
Line count of the encoder used
Default:
2048 [incr.]
MP_posEncoderDist
MP_posEncoderIncr
--------------------------------------------------------------------