412
ACU-RITE Technical Manual MILLPWR
G2
Retract tool at NC
stop
In the parameter object
CfgLiftOff,
you define the reaction of the tool to NC
stop:
In
MP_on,
you define whether the tool is to lift off at NC stop.
In
MP_distance,
you define the retraction height.
MP_on
Switching on/off lift-off movements during NC stop
Selection:
[ On ]
Lift-off movements active
[ Off ]
Lift-off movements not active
Default:
Off
MP_distance
Maximum retraction height for NC stop
Format:
Numeric value
Input:
0.000000000 to 2.000000000 [mm
Default: 0.0 [mm]
Settings in the configuration editor:
NCchannel
ChannelSettings
Key for channel
CfgLiftOff
on