Define the path-specific limit values for feed rate, acceleration and jerk.
The feed rate minimum defined in MP_minPathFeed is only violated within a
segment if a lower feed rate is programmed.
MP_minPathFeed
Minimum feed rate on the path
Format:
Numeric value
Input:
0.000 000 000 to 600 000 [mm/min]
Default:
60 [mm/min]]
Settings in the configuration editor:
NCchannel
channelSettings
Key for channel
CfgLaPath
minPathFeed
minCornerFeed
maxG1Feed
maxPathJerk
maxPathJerkHi
pathTolerance
pathToleranceHi
maxPathYank