4.7 Overview of the Machine Parameters
239
type
402303
Type of coupling
Format:
Selection menu
Input:
Static
:
Static coupling – is automatically closed in the
start-up phase without PLC involvement.
Dynamic
:
Dynamic coupling – is closed only by PLC com-
mand.
Default:
Static
RUN
LEVEL3
597 110-04
typeOfOffset
402304
MP860.x, bit 0
Specifies how the position offset between
master and slave axis is treated.
Format:
Selection menu
Input:
None / Actual
:
The offset when a coupling is closed is retained
as static offset. There is no compensating
movement on stationary axes.
Parameter
:
After the reference run, the value of the para-
meter
MP_posOffset
is taken as the absolute
position offset. When the coupling closes there
is an immediate compensating movement.
Default:
None
RUN
LEVEL3
posOffset
402305
MP855.x
Value of the position offset with closed cou-
pling
Format:
Numeric value
Input:
Position offset [mm] or [°] that is compensated
and maintained if
MP_typeOfOffset
=
Parameter
is set.
Default:
0
RUN
LEVEL3
597 110-04
offsetFeed
402306
MP1330.x
The velocity at with which an offset between
the master axis and the slave axis is compen-
sated for
Format:
Numeric value
Input:
Speed in [mm/min] or
[°/min]
Default:
999.996 [mm/min] or [°/min]
RUN
LEVEL3
597 110-04
maxPosDiff
402307
MP855.x
Synchronization monitoring – deletable emer-
gency stop message
Format:
Numeric value
Input:
Permissible offset [mm]
Default:
0
RUN
LEVEL3
597 110-04
Parameter
MP number
Function and input
Reaction/Access
Содержание MILLPWR G2
Страница 1: ...Technical Manual ACU RITE MILLPWRG2 ...
Страница 2: ......
Страница 14: ...14 ACU RITE Technical Manual MILLPWRG2 ...
Страница 40: ...40 ACU RITE Technical Manual MILLPWRG2 ...
Страница 56: ...56 ACU RITE Technical Manual MILLPWRG2 3 10 Dimensions 3 10 1 MILLPWRG2 Weight 8 0 kg Dim Inch mm ...
Страница 58: ...58 ACU RITE Technical Manual MILLPWRG2 3 10 3 USB Hub ...
Страница 60: ...60 ACU RITE Technical Manual MILLPWRG2 TS 220 Adapter cable for TS 120 TS 220 ...
Страница 61: ...3 10 Dimensions 61 SE 640 transmitter receiver unit ...
Страница 62: ...62 ACU RITE Technical Manual MILLPWRG2 SE 540 transmitter receiver unit ...
Страница 63: ...3 10 Dimensions 63 TS 440 TS 640 ...
Страница 64: ...64 ACU RITE Technical Manual MILLPWRG2 ...
Страница 392: ...392 ACU RITE Technical Manual MILLPWRG2 ...
Страница 545: ......