6.3 Switching the Control On/Off
397
6.3 Switching the Control On/Off
6.3.1 Powering Up the Control
Message for power
interruption
In
MP_powerInterruptMsg,
you define the behavior during control start-up.
You can choose between the following start-up procedures.
The message
Power interrupted
is displayed during control start-up. Run-
up is only continued after the message has been acknowledged.
Run-up is not interrupted. The message
Power interrupted
does not
appear.
MP_powerInterruptMsg
Acknowledge the “Power interrupted“ message
Format:
Selection menu
Selection:
[ True ]
Run-up is only continued after the message has been acknowl-
edged.
[ False ]
The “Power interrupted” message does not appear.
Default:
False
Settings in the configuration editor:
System
DisplaySettings
CfgStartupData
powerInterruptMsg
PLC operand
Set
MNN_GenCycleAfterPowerOn
1st PLC scan after power on
+X
MNN_GenCycleAfterPlcStop
1st PLC scan after PLC interruption
+Y
MNN_GenCycleAfterReConfig
1st PLC scan after change of configuration data
MNN_GenCycleInitialized
Control is being initialized (after start-up cycles)
+Z
Содержание MILLPWR G2
Страница 1: ...Technical Manual ACU RITE MILLPWRG2 ...
Страница 2: ......
Страница 14: ...14 ACU RITE Technical Manual MILLPWRG2 ...
Страница 40: ...40 ACU RITE Technical Manual MILLPWRG2 ...
Страница 56: ...56 ACU RITE Technical Manual MILLPWRG2 3 10 Dimensions 3 10 1 MILLPWRG2 Weight 8 0 kg Dim Inch mm ...
Страница 58: ...58 ACU RITE Technical Manual MILLPWRG2 3 10 3 USB Hub ...
Страница 60: ...60 ACU RITE Technical Manual MILLPWRG2 TS 220 Adapter cable for TS 120 TS 220 ...
Страница 61: ...3 10 Dimensions 61 SE 640 transmitter receiver unit ...
Страница 62: ...62 ACU RITE Technical Manual MILLPWRG2 SE 540 transmitter receiver unit ...
Страница 63: ...3 10 Dimensions 63 TS 440 TS 640 ...
Страница 64: ...64 ACU RITE Technical Manual MILLPWRG2 ...
Страница 392: ...392 ACU RITE Technical Manual MILLPWRG2 ...
Страница 545: ......