5.14 Monitoring Functions
365
MP_servoLagMin1/2 applies for constant feed rates, MP_servoLagMax1/2
during changes in feed rate.
MP_servoLagMin1
Minimum value for following-error monitoring (clearable)
Format:
Numerical values
Input:
0.000 000 000 to 100 [mm] or [°]
Default:
1 [mm] or [°]
MP_servoLagMax1
Maximum value for following-error monitoring (clearable)
Format:
Numerical values
Input:
0.000 000 000 to 100 [mm] or [°]
Default:
5 [mm] or [°]
MP_servoLagMin2
Minimum value for following-error monitoring (emergency stop)
Format:
Numerical values
Input:
0.000 000 000 to 100 [mm] or [°]
Default:
1 [mm] or [°]
Sa (V)
t
v
servoLagMax1
servoLagMax2
servoLagMin1
servoLagMin2