420
ACU-RITE Technical Manual MILLPWR
G2
M, S or T function in
parallel with
traverse motion
The PLC can execute M, S or T functions in parallel with the movement pro-
grammed in the same NC block.
Modul 9404 Start movement when an NC strobe is present
The module starts the movement programmed in an NC block when a strobe
that is effective at the beginning of the same NC block is still present.
Call:
PS
b/w/d/k
<>Channel number>
CM
9404
PL
b/w/d
<Error number>
0: Successful
1: Invalid channel number
2: Execution of NC part program is not synchronized
15: Module was called in a spawn job or submit job
Error code:
Marker
Value Meaning
NN_GenApiModule
Error
0
Movement successfully started
1
Process not possible
Содержание MILLPWR G2