356
ACU-RITE Technical Manual MILLPWR
G2
Compensation of
reversal peaks
For adjusting the compensation of the reversal peaks, proceed as follows:
Set machine parameter
MP_compFFAdjust
= 0 and
MP_compRefAcc
= 0
to ensure that the compensation strength is constant over all feed-rate val-
ues.
Now select a typical machining speed and adjust the
MP_compStrength,
MP_compWidth
and
MP_compTimeOffset
parameters for the selected
speed.
MP_compWidth
specifies the duration of compensation and should contain
values in the range of a few microns.
In
MP_compStrength
specify the distance (in [mm]) which the axis will
travel if it ideally complies with the transferred nominal speed value. The
reversal peak height resulting without compensation is a suitable starting
value for the compensation.
In
MP_compWidth,
enter the duration of compensation. The value entered
should lie in the range of a few microns.
Set the parameter
MP_compTimeOffset
= 0.
Run a circular interpolation test.
If the path traversed in the circular test deviates at the reversal point from
the nominal path, first toward the inside and then toward the outside, the
compensation is performed too early. In this case, you must increase the
value in
MP_compTimeOffset.
If the path traversed deviates at the reversal point from the nominal path,
first toward the outside and then toward the inside, the compensation is
performed too late. In this case, you must decrease the value in
MP_compTimeOffset.
With the following formula you can estimate the magnitude of useful values
for the
MP_compTimeOffset
parameter:
It is easier to adjust the
MP_compWidth
and
MP_compTimeOffset
parame-
ters at low feed rates. HEIDENHAIN recommends:
First roughly adjust
MP_compStrength.
Then select a low feed rate.
Then set
MP_compWidth
and
MP_compTimeOffset.
Return to the original feed rate and optimize the value for
MP_compStrength.
compTimeOffset
2
acceleration
[
]
compWidth
⋅
⋅
6
⋅
=
Содержание MILLPWR G2
Страница 1: ...Technical Manual ACU RITE MILLPWRG2 ...
Страница 2: ......
Страница 14: ...14 ACU RITE Technical Manual MILLPWRG2 ...
Страница 40: ...40 ACU RITE Technical Manual MILLPWRG2 ...
Страница 56: ...56 ACU RITE Technical Manual MILLPWRG2 3 10 Dimensions 3 10 1 MILLPWRG2 Weight 8 0 kg Dim Inch mm ...
Страница 58: ...58 ACU RITE Technical Manual MILLPWRG2 3 10 3 USB Hub ...
Страница 60: ...60 ACU RITE Technical Manual MILLPWRG2 TS 220 Adapter cable for TS 120 TS 220 ...
Страница 61: ...3 10 Dimensions 61 SE 640 transmitter receiver unit ...
Страница 62: ...62 ACU RITE Technical Manual MILLPWRG2 SE 540 transmitter receiver unit ...
Страница 63: ...3 10 Dimensions 63 TS 440 TS 640 ...
Страница 64: ...64 ACU RITE Technical Manual MILLPWRG2 ...
Страница 392: ...392 ACU RITE Technical Manual MILLPWRG2 ...
Страница 545: ......