5.13 The Control Loop
343
You can influence feedback control with velocity feedforward with the kv fac-
tor:
Enter a kv factor in
MP_kvFactor.
Unlike operation with following error, you must enter the optimum kv factor
for each axis when operating with interpolated axes.
U [V]
t [ms]
Attention
If the k
v
factor that you select is too large, the system will oscillate around
the forward-fed nominal velocity value.
Содержание MILLPWR G2