PLC Module 9035 (Reading the status information)
The module supports status information #0 to #3, #5 to #8 and #16 as well:
Transferred number
Return code
0
Main operating mode of editor
0:
Programming and Editing
1:
Test Run
1
Main operating mode of machine
0:
Traverse Reference Points
1:
Manual Operation
2:
Electronic Handwheel
3:
Positioning with Manual Data Input
4:
Program Run, Single Block
5:
Program Run, Full Sequence
2
Operating mode in front of editor
0: None (main operating mode active)
1: MOD active
2: Program management/external interfaces active
3: MP editor active
4: PLC programming active
3
Operating mode in front of machine
0: None (main operating mode active)
1: MOD active
2: Program management/external interfaces active
3: Tool table selected
4: Pocket table selected
5: Other table editor active
5
Selected file in
Programming and Edi-
ting
or
Test Run
0: No file
1: *.H (conversational NC PGM)
2: *.I (ISO NC PGM)
3: *.T (tool table)
4: *.D (datum table)
5: *.P (pallet table)
6: *.A (ASCII file)
7: *.TCH (pocket table)
6
Selected file in
Program Run, Full
Sequence
and
Program Run, Single
Block
0: No file
1: *.H (conversational NC PGM)
2: *.I (ISO NC PGM)
7
Selected axis for actual position cap-
ture in
Programming and Editing
mode
0: X axis
1: Y axis
2: Z axis
3: IV axis
4: V axis
5: VI axis
6: VII axis
etc.
8
Selected machine axis
(for actual-position-capture)
0: X axis
1: Y axis
2: Z axis
3: IV axis
4: V axis
5: VI axis
6: VII axis
etc.
16
Input format of the $MDI file
0: *.H (conversational NC PGM)
1: *.I file (ISO NC PGM)
Содержание MILLPWR G2
Страница 1: ...Technical Manual ACU RITE MILLPWRG2 ...
Страница 2: ......
Страница 14: ...14 ACU RITE Technical Manual MILLPWRG2 ...
Страница 40: ...40 ACU RITE Technical Manual MILLPWRG2 ...
Страница 56: ...56 ACU RITE Technical Manual MILLPWRG2 3 10 Dimensions 3 10 1 MILLPWRG2 Weight 8 0 kg Dim Inch mm ...
Страница 58: ...58 ACU RITE Technical Manual MILLPWRG2 3 10 3 USB Hub ...
Страница 60: ...60 ACU RITE Technical Manual MILLPWRG2 TS 220 Adapter cable for TS 120 TS 220 ...
Страница 61: ...3 10 Dimensions 61 SE 640 transmitter receiver unit ...
Страница 62: ...62 ACU RITE Technical Manual MILLPWRG2 SE 540 transmitter receiver unit ...
Страница 63: ...3 10 Dimensions 63 TS 440 TS 640 ...
Страница 64: ...64 ACU RITE Technical Manual MILLPWRG2 ...
Страница 392: ...392 ACU RITE Technical Manual MILLPWRG2 ...
Страница 545: ......