Installation and Operation Manual
Chapter
6 Monitoring and Diagnostics
ACE-3105, ACE-3205 Ver. 5.2
Monitoring Performance
6-23
Parameter Description
Possible
Values
Wire pair
The SHDSL wire-pair number for
which the statistics are
displayed.
1 – 4
Default: 1
³
To view the SHDSL port statistics:
•
Select Statistics.
The statistic parameters of SHDSL Port 1 appear listed (
and
).
ACE-3205 – RAD Data Communications
Monitoring> Physical layer > Port > SHDSL > Statistics
LOSW ... (0)
CRC anomalies ... (0)
ES ... (0)
SES ... (0)
UAS ... (0)
Time elapsed ... (0)
Valid intervals ... (0)
1. Interval ... (0)
2. Port number ... (1)
3. Wire pair ... (1)
>
Please select item <1 to 3>
ESC-Previous menu; !-Main menu; &-Exit; @-Debug
Figure
6-20. SHDSL Port Statistics
Table
6-17. SHDSL Port Statistics
Parameter Description
Possible
Values
LOSW
Number of seconds where Loss Of
Sync Word events have been
detected.
CRC anomalies
Number of errors detected by cyclic
redundancy checks.
ES
Number of Errored Seconds where one
or more CRC error events or one or
more LOSW error events have been
detected. This parameter is inhibited
during UAS state.
Содержание ACE-3205
Страница 1: ...ACE 3105 ACE 3205 Cell Site Gateways Version 5 2 INSTALLATION AND OPERATION MANUAL The Access Company...
Страница 2: ......
Страница 352: ...Chapter 6 Monitoring and Diagnostics Installation and Operation Manual 6 114 Technical Support ACE 3105 ACE 3205 Ver 5 2...
Страница 380: ...Appendix D Clock Modes Installation and Operation Manual D 8 DSL and PSN Timing Modes ACE 3105 ACE 3205 Ver 5 2...
Страница 396: ...Appendix E Encapsulation over PSN Installation and Operation Manual E 16 5BClock Encapsulation ACE 3105 ACE 3205 Ver 5 2...
Страница 414: ......
Страница 416: ......
Страница 417: ......