6 Monitoring and Diagnostics
ACE-3105, ACE-3205 Ver. 5.2
Monitoring Performance
6-21
Parameter Description
Possible
Values
SES
Number of Severely Errored Second.
This parameter is a count of 1-
second intervals with 18 or more
CRC-8 anomalies summed over all
received bearer channels, or one or
more LOS defects, or one or more
SEF defects, or one or more LPR
defects. This parameter is inhibited
during UAS.
UAS
Number of Unavailable Second.
Unavailability state begins at the
onset of 10 contiguous severely
Errored seconds, and ends at the
onset of 10 contiguous seconds with
no severely Errored seconds.
Time elapsed or
Start Time
The elapsed time since the beginning
of the current interval.
0 – 899
Valid Intervals
The number of intervals saved.
0 – 24
Interval
The number of the interval to be
displayed
0 – 24
(or the number of existing
intervals).
Default: 0
Port Number
The ADSL port number for which
the status is displayed.
1 – 2
Default: 1
Viewing the SHDSL Port Status and Statistics
The SHDSL statistics refer to the actual upstream rate as well as the actual
transmitting power etc.
³
To access the SHDSL menu:
•
From the Port monitoring menu (see
), select SHDSL.
The SHDSL menu appears.
³
To view the SHDSL port status:
•
Select Status.
The status parameters of SHDSL Port 1 appear listed (
and
).
Содержание ACE-3205
Страница 1: ...ACE 3105 ACE 3205 Cell Site Gateways Version 5 2 INSTALLATION AND OPERATION MANUAL The Access Company...
Страница 2: ......
Страница 352: ...Chapter 6 Monitoring and Diagnostics Installation and Operation Manual 6 114 Technical Support ACE 3105 ACE 3205 Ver 5 2...
Страница 380: ...Appendix D Clock Modes Installation and Operation Manual D 8 DSL and PSN Timing Modes ACE 3105 ACE 3205 Ver 5 2...
Страница 396: ...Appendix E Encapsulation over PSN Installation and Operation Manual E 16 5BClock Encapsulation ACE 3105 ACE 3205 Ver 5 2...
Страница 414: ......
Страница 416: ......
Страница 417: ......