Chapter
4 Configuration
Installation and Operation Manual
4-54
Configuring for Operation
ACE-3105, ACE-3205 Ver. 5.2
ACE-3205 – RAD Data Communications
Configuration> System> Clock> Fallback clock
1. Source > (RX Clock)
2. Port type > (SHDSL)
3. Port number ... (1)
4. Station clock type > (1)
>
Please select item <1 to 4>
ESC-previous menu; !-main menu; &-exit
Figure
4-42. Fallback Clock Menu
Table
4-36. Fallback Clock Parameters
Parameter Description
Possible
Values
Source
The clock source type
•
RX Clock – the clock is
derived from the incoming
traffic of one of the unit's
ports.
•
Recovered – the clock is
recovered from the PSN.
•
None – No port is
assigned to be a system
clock source. This value is
not available for the
primary clock.
Port type
Type of the master clock port. Visible only
if RX Clock was selected as the clock
source.
Note:
•
This parameter only shows if the source
is set to RX Clock.
•
If the port type is IMA group, only an
existing IMA group with at least one link
that is assigned to the group may be
selected.
•
E1/T1 – One of the E1, T1
or J1 ports
•
IMA group – Timing
Reference Link (TRL) of an
IMA group is to be
assigned as a source for
the master clock.
•
SHDSL
Default: None
Содержание ACE-3205
Страница 1: ...ACE 3105 ACE 3205 Cell Site Gateways Version 5 2 INSTALLATION AND OPERATION MANUAL The Access Company...
Страница 2: ......
Страница 352: ...Chapter 6 Monitoring and Diagnostics Installation and Operation Manual 6 114 Technical Support ACE 3105 ACE 3205 Ver 5 2...
Страница 380: ...Appendix D Clock Modes Installation and Operation Manual D 8 DSL and PSN Timing Modes ACE 3105 ACE 3205 Ver 5 2...
Страница 396: ...Appendix E Encapsulation over PSN Installation and Operation Manual E 16 5BClock Encapsulation ACE 3105 ACE 3205 Ver 5 2...
Страница 414: ......
Страница 416: ......
Страница 417: ......