RDRE1
C1
C2
C3
C4
C5
C6
C7
C8
C9
C10
C11
C12
C13
C14
C15
C16
C17
C18
C19
C20
C21
C22
C23
C24
C25
C26
C27
C28
C29
C30
C31
C32
C33
C34
C35
C36
C37
C38
C39
C40
C41
C42
C43
C44
C45
C46
C47
C48
C49
C50
C51
C52
C53
C54
C55
C56
C57
C58
C59
C60
C61
C62
C63
C64
TRIGGERED
OR6
B1
B2
B3
B4
B5
B6
O
OR6
B1
B2
B3
B4
B5
B6
O
OR
B1
B2
O
OR6
B1
B2
B3
B4
B5
B6
O
OR6
B1
B2
B3
B4
B5
B6
O
OR6
B1
B2
B3
B4
B5
B6
O
OR6
B1
B2
B3
B4
B5
B6
O
OR6
B1
B2
B3
B4
B5
B6
O
OR6
B1
B2
B3
B4
B5
B6
O
OR6
B1
B2
B3
B4
B5
B6
O
OR6
B1
B2
B3
B4
B5
B6
O
OR
B1
B2
O
OR
B1
B2
O
CCBRBRF1_TRBU
X120_BI3_CB_OPENED
X120_BI2_CB_CLOSED
DARREC1_CLOSE_CB
PHIPTOC1_OPERATE
DPHLPDOC2_OPERATE
DPHHPDOC1_OPERATE
NSPTOC1_OPERATE
DPHLPDOC1_OPERATE
NSPTOC2_OPERATE
EFPADM1_OPERATE
EFPADM2_OPERATE
EFPADM3_OPERATE
INTRPTEF1_OPERATE
PDNSPTOC1_OPERATE
ROVPTOV1_OPERATE
ROVPTOV2_OPERATE
ROVPTOV3_OPERATE
DEFHPDEF1_OPERATE
DEFLPDEF1_OPERATE
DEFLPDEF2_OPERATE
EFHPTOC1_OPERATE
WPWDE1_OPERATE
WPWDE2_OPERATE
WPWDE3_OPERATE
PHPTOV1_OPERATE
PHPTOV2_OPERATE
PHPTOV3_OPERATE
PHPTUV1_OPERATE
PSPTUV1_OPERATE
NSPTOV1_OPERATE
PHPTUV2_OPERATE
PHPTUV3_OPERATE
ARCSARC1_OPERATE
ARCSARC2_OPERATE
ARCSARC3_OPERATE
CCBRBRF1_TRRET
DPHLPDOC1_START
DPHLPDOC2_START
DPHHPDOC1_START
PHIPTOC1_START
NSPTOC1_START
NSPTOC2_START
DEFLPDEF1_START
DEFLPDEF2_START
DEFHPDEF1_START
INTRPTEF1_START
EFHPTOC1_START
PDNSPTOC1_START
PHPTOV1_START
PHPTOV2_START
PHPTOV3_START
PSPTUV1_START
NSPTOV1_START
PHPTUV1_START
PHPTUV2_START
PHPTUV3_START
ROVPTOV1_START
ROVPTOV2_START
ROVPTOV3_START
EFPADM1_START
EFPADM2_START
EFPADM3_START
WPWDE1_START
WPWDE2_START
WPWDE3_START
X120_BI1_EXT_OC_BLOCKING
CCSPVC1_FAIL
SEQSPVC1_FUSEF_U
T1PTTR1_START
INRPHAR1_BLK2H
SEQSPVC1_FUSEF_3PH
DARREC1_INPRO
T1PTTR1_OPERATE
ARCSARC1_ARC_FLT_DET
ARCSARC2_ARC_FLT_DET
ARCSARC3_ARC_FLT_DET
DARREC1_UNSUC_RECL
DISTURB_RECORD_TRIGGERED
GUID-EA71AC89-D293-4E85-9B21-3E36DA2EEFEF V3 EN
Figure 245:
Disturbance recorder
3.8.3.3
Functional diagrams for condition monitoring
Failures in current measuring circuits are detected by CCSPVC1. When a failure is
detected, it can be used to block the current protection functions that are measuring the
calculated sequence component currents or residual current to avoid unnecessary
operation.
CCSPVC1
BLOCK
FAIL
ALARM
CCSPVC1_FAIL
CCSPVC1_ALARM
GUID-31249D4E-19AA-42E0-AD46-C6720DD67A53 V2 EN
Figure 246:
Current circuit supervision function
The fuse failure supervision SEQSPVC1 detects failures in the voltage measurement
circuits. Failures, such as an open MCB, raise an alarm.
SEQSPVC1
BLOCK
CB_CLOSED
DISCON_OPEN
MINCB_OPEN
FUSEF_3PH
FUSEF_U
X120_BI2_CB_CLOSED
X110_BI1_MCB_OPENED
SEQSPVC1_FUSEF_3PH
SEQSPVC1_FUSEF_U
GUID-83FF05A1-16D5-41C2-BCD2-39A0D7033704 V2 EN
Figure 247:
Fuse failure supervision function
Circuit-breaker condition monitoring SSCBR1 supervises the switch status based on
the connected binary input information and the measured current levels. SSCBR1
introduces various supervision methods.
1MRS756378 S
Section 3
REF615 standard configurations
REF615
185
Application Manual