64 Start-up
8. Perform the PDO configuration as follows:
•
In the
PDO List
box, select a PDO.
•
In the
PDO Content
box, edit the object mapping of the
selected PDO.
•
In the
Sync Manager
and
PDO Assignment
boxes,
assign the selected PDOs to the Sync managers.
•
Check that the
PDO Assignment
and
PDO
Configuration
check boxes are selected to make
TwinCAT transfer the configuration to the module when the
network is started. In the Config Mode, the network can be
restarted by reloading the I/O devices (by pressing F4).
9. Create a task in TwinCAT: Right-click
Additional Tasks
and
select
Append task
. Link the adapter module’s inputs and
outputs to the appended task's input and output variables.