Start-up 37
27
FBA PAR
REFRESH
Validates any changed adapter module
configuration parameter settings. After
refreshing, the value reverts automatically to
0
= Done.
Note:
This parameter cannot be changed
while the drive is running.
0
= Done
ACS355/ACSM1:
FBA PAR
REFRESH
ACS850/ACS880/
ACS580:
FBA par refresh
0
= Done
Refreshing done
1
=
Refresh/Configure
Refreshing
28
PAR TABLE VER
Read-only.
Displays the parameter table
revision of the fieldbus adapter module
mapping file stored in the memory of the
drive.
N/A
ACS355:
FILE CPI FW REV
ACSM1:
PAR TABLE VER
ACS850/ACS880/
ACS580:
Par table ver
Parameter table revision
29
DRIVE TYPE
CODE
Read-only.
Displays the drive type code of
the fieldbus adapter module mapping file
stored in the memory of the drive.
N/A
ACS355:
FILE CONFIG ID
ACSM1:
DRIVE TYPE
CODE
ACS850/ACS880/
ACS580:
Drive type code
Drive type code of the fieldbus adapter
module mapping file
No.
Name/Value
Description
Default