Appendix A – CoE Object Dictionary 127
604A
0 vl velocity
quick stop
U8
RO
Quick stop ramp set-
tings for the vl opera-
tion mode
1 Delta speed U32
RW
Ramp delta speed (vl
scaling units).
Note:
Read only in
ACS355, ACS580 and
ACS880.
Drv
2 Delta time
U16
RW
Ramp delta time (s)
Drv
604C
0 vl dimen-
sion factor
U8
R
Velocity data scaling
factor for the vl opera-
tion mode. Basic unit
in the vl operation
mode is rpm.
1 numerator
I32
RW
Default: 1
FBA
2 denomina-
tor
I32
RW
Default: 1
FBA
605B
Shutdown
option code
I16
RW
0 = coast stop (de-
fault)
1 = ramp stop
FBA
605C
Disable op-
eration op-
tion code
I16
RW
0 = coast stop
1 = ramp stop (de-
fault)
FBA
605D
Halt option
code
I16
RW
vl mode.
1 = force ramp gener-
ator input to zero (de-
fault)
2…4 = force ramp
generator output to
zero
Note:
Halt does not
cause the drive to
stop, merely to run at
a zero speed.
FBA
Index SI
Name
Type
Ac-
cess
PM
Information
NVS
Содержание FECA-01 EtherCAT
Страница 1: ...Options for ABB drives converters and inverters User s manual FECA 01 EtherCAT adapter module ...
Страница 4: ......
Страница 10: ...10 Table of contents ...
Страница 14: ...14 Safety instructions ...
Страница 28: ...28 Mechanical installation ...
Страница 32: ...32 Electrical installation ...
Страница 63: ...Start up 63 ...
Страница 66: ...66 Start up ...
Страница 86: ...86 Communication profiles ...