76 Start-up
9. Save the valid parameter values to permanent memory by
setting parameter
96.07 Param save
to Save.
10. To validate the settings made in the parameter groups
51
,
52
and
53
, set parameter
51.27 FBA par refresh
to Configure.
11. Set the relevant drive control parameters to control the drive
according to the application.
Examples of appropriate values are shown in the tables below.
Parameter setting examples – ACS880
CiA 402 Velocity mode with default PDO mapping
This example shows how to configure a basic speed control
application that uses CiA 402 profile. The start/stop commands are
according to the CiA 402 profile velocity control mode.
Rx PDO1 and Tx PDO1 are enabled by default.
Note:
The Tx PDO1 default transmission type is 255
(asynchronous) and event time is 0. The event time should be
changed with CANopen object 1800h05 if the default transmission
type is used.
PDO
Word 1
Length
Rx PDO1
6040h Control word
16 bits
Tx PDO1
6041h Status word
16 bits
Содержание FCAN-01
Страница 1: ... OPTION FOR ABB DRIVES CONVERTERS AND INVERTERS FCAN 01 CANopen adapter module User s manual ...
Страница 4: ......
Страница 10: ...10 Table of contents ...
Страница 14: ...14 Safety instructions ...
Страница 30: ...30 Mechanical installation ...
Страница 36: ...36 Electrical installation ...
Страница 81: ...Start up 81 ...
Страница 82: ...82 Start up 8 Configure the FCAN 01 properties Select the node boot up sequence ...
Страница 108: ...108 Communication profiles ...
Страница 152: ...152 Communication protocol ...
Страница 156: ...156 Diagnostics ...
Страница 160: ...160 Technical data ...
Страница 164: ...164 Appendix A Dictionary structure and entries ...
Страница 173: ...Appendix B CANopen error codes 173 FFFF Manufacturer specific Error code hex Meaning ...
Страница 174: ...174 Appendix B CANopen error codes ...