140 Communication protocol
1800
0
Transmit
PDO1
Parame-
ter
U8
RO
Number of entries
1
COB ID
U32
RW
Default: 180h + Node ID
2
Trans-
mission
Type
U8
RW
Default: 255 (asynchronous
transmission)
2)
3
Inhibit
Time
U16
RW
Minimum interval for PDO
transmission (= value x 100
microseconds)
5
Event
Timer
U16
RW
0...65535 ms
0 = Not used
Default: 0
1A00
0
Transmit
PDO1
Mapping
U8
RW
Number of mapped objects,
0...4
3)
1
Mapped
Obj 1
U32
RW
Default: 60410010h = 6041h
Status word
3)
. See
.
2
Mapped
Obj 2
U32
RW
3
Mapped
Obj 3
U32
RW
4
Mapped
Obj 4
U32
RW
Index
(hex)
Sub-
index
Name
Type
Attri-
bute
Information
Содержание FCAN-01
Страница 1: ... OPTION FOR ABB DRIVES CONVERTERS AND INVERTERS FCAN 01 CANopen adapter module User s manual ...
Страница 4: ......
Страница 10: ...10 Table of contents ...
Страница 14: ...14 Safety instructions ...
Страница 30: ...30 Mechanical installation ...
Страница 36: ...36 Electrical installation ...
Страница 81: ...Start up 81 ...
Страница 82: ...82 Start up 8 Configure the FCAN 01 properties Select the node boot up sequence ...
Страница 108: ...108 Communication profiles ...
Страница 152: ...152 Communication protocol ...
Страница 156: ...156 Diagnostics ...
Страница 160: ...160 Technical data ...
Страница 164: ...164 Appendix A Dictionary structure and entries ...
Страница 173: ...Appendix B CANopen error codes 173 FFFF Manufacturer specific Error code hex Meaning ...
Страница 174: ...174 Appendix B CANopen error codes ...