![ABB ACH550-BCR Скачать руководство пользователя страница 510](http://html.mh-extra.com/html/abb/ach550-bcr/ach550-bcr_user-manual_2927510.webp)
2-164
ACH550 E-Clipse Bypass User’s Manual
Embedded fieldbus
Note:
For Present Value Access Types, R = Read-only, W = Writeable,
C = Commandable. Commandable values support priority arrays & relinquish
defaults.
Analog value object instance summary – drive
The following table summarizes the Analog Value Objects supported:
Instance
ID
Object Name
Description
Units
Present Value
Access Type
AV0
OUTPUT
SPEED
This object indicates the calculated motor
speed in RPM. The corresponding drive
parameter is 0102.
RPM
R
AV1
OUTPUT FREQ This object indicates the output
frequency applied to the motor in Hz. The
corresponding drive parameter is 0103.
Hertz
R
AV2
DC BUS VOLT
This object indicates the drive’s DC bus
voltage level. The corresponding drive
parameter is 0107.
Volts
R
AV3
OUTPUT VOLT
This object indicates the AC output
voltage applied to the motor. The
corresponding drive parameter is 0109.
Volts
R
AV4
CURRENT
This object indicates the measured
output current. The corresponding drive
parameter is 0104.
Amps
R
AV5
TORQUE
This object indicates the calculated motor
output torque as a percentage of nominal
torque. The corresponding drive
parameter is 0105.
Percent
R
AV6
POWER
This object indicates the measured
output power in kW. The corresponding
drive parameter is 0106.
Kilowatts
R
AV7
DRIVE TEMP
This object indicates the measured
heatsink temperature in °C. The
corresponding drive parameter is 0110.
°C
R
AV8
KWH (R)
This object indicates, in kW hours, the
drive’s accumulated energy usage since
the last reset. The value can be reset to
zero. The corresponding drive parameter
is 0115.
kWh
W
AV9
KWH (NR)
This object indicates the drive’s
accumulated energy usage in MW hours.
The value cannot be reset.
MWh
R
AV10
PRC PID FBCK This object is the Process PID feedback
signal. The corresponding drive
parameter is 0130.
Percent
R
AV11
PRC PID DEV
This object is the Process PID output
signal’s deviation from its setpoint. The
corresponding drive parameter is 0132.
Percent
R
AV12
EXT PID FBCK
This object is the External PID feedback
signal. The corresponding drive
parameter is 0131.
Percent
R
Содержание ACH550-BCR
Страница 4: ...iv Manual contents ...
Страница 5: ...ACH550 UH User s Manual 1 1 ACH550 UH HVAC Drives 1 550 HP User s Manual 2016 ABB All Rights Reserved ...
Страница 6: ......
Страница 12: ...1 8 ACH550 UH User s Manual Table of contents ...
Страница 36: ...1 32 ACH550 UH User s Manual Installation ...
Страница 70: ...1 66 ACH550 UH User s Manual Application macros ...
Страница 335: ...ACH550 UH User s Manual 1 331 Technical data ...
Страница 348: ......
Страница 382: ...2 36 ACH550 E Clipse Bypass User s Manual Start up ...
Страница 398: ...2 52 ACH550 E Clipse Bypass User s Manual Bypass functions overview ...
Страница 406: ...2 60 ACH550 E Clipse Bypass User s Manual Application macros ...
Страница 544: ...2 198 ACH550 E Clipse Bypass User s Manual Embedded fieldbus ...
Страница 584: ...2 238 ACH550 E Clipse Bypass User s Manual Diagnostics ...
Страница 608: ......
Страница 612: ...3 6 ACH550 UH User s Manual Table of contents ...
Страница 622: ...3 16 ACH550 PCR PDR User s Manual Installation ...
Страница 641: ......