![ABB ACH550-BCR Скачать руководство пользователя страница 117](http://html.mh-extra.com/html/abb/ach550-bcr/ach550-bcr_user-manual_2927117.webp)
ACH550-UH User’s Manual
1-113
Parameters
Commissioning the override mode:
1. Enter the parameters in all groups as needed, except group 17. Run Enable/Start
Enable inputs configured prior to enabling the override mode will be acknowledged
in override. Inputs configured after enabling override will be ignored (Low priority
safeties).
2. Select the digital input that will activate override mode P1701.
3. Enter the frequency or speed reference for override mode, P1702 and P1703,
according to the motor control mode P9904.
4. Enter the pass code P1704 (358).
5. Enable the override mode P1705.
Changing the override parameters:
1. If override mode is already enabled, disable it:
• Enter the pass code P1704.
• Disable the override mode P1705.
2. If needed, load the override parameter set P9902.
3. Change the parameters as needed, except group 17.
4. Change the parameters in group 17 as needed:
• Digital input for override mode P1701.
• Frequency or speed reference, P1702 or P1703.
5. Enter the pass code P1704.
6. Enable the override mode P1705. The drive replaces the override parameter set with
new values of all parameters.
1002
PAR PFA IOCONF
1003
PAR AI SCALE
1004
PAR AO SCALE
1006
PAR EXTROMISSING
1007
PAR FBUSMISSING
1008
PAR PFAWOSCALAR
Group 17: Override
Code Description Range
Resolution
Default
S
1701
OVERRIDE SEL
-6…6
1
0 (
NOT
SEL
)
Selects the source of the override activation signal.
0 =
NOT
SEL
– Override activation signal not selected.
1 =
DI
1 – Defines digital input DI1 as the override activation signal.
• This digital input must be activated for override activation signal.
2…6 =
DI
2…
DI
6 – Defines digital input DI2…DI6 as the override activation signal.
• See DI1 above.
(-1) =
DI
1(
INV
) – Defines an inverted digital input DI1 as the override activation signal.
(-2)…(-6) =
DI
2(
INV
)…
DI
6(
INV
) – Defines an inverted digital input DI2…DI6 as the override activation signal.
• See
DI
1(
INV
) above.
Содержание ACH550-BCR
Страница 4: ...iv Manual contents ...
Страница 5: ...ACH550 UH User s Manual 1 1 ACH550 UH HVAC Drives 1 550 HP User s Manual 2016 ABB All Rights Reserved ...
Страница 6: ......
Страница 12: ...1 8 ACH550 UH User s Manual Table of contents ...
Страница 36: ...1 32 ACH550 UH User s Manual Installation ...
Страница 70: ...1 66 ACH550 UH User s Manual Application macros ...
Страница 335: ...ACH550 UH User s Manual 1 331 Technical data ...
Страница 348: ......
Страница 382: ...2 36 ACH550 E Clipse Bypass User s Manual Start up ...
Страница 398: ...2 52 ACH550 E Clipse Bypass User s Manual Bypass functions overview ...
Страница 406: ...2 60 ACH550 E Clipse Bypass User s Manual Application macros ...
Страница 544: ...2 198 ACH550 E Clipse Bypass User s Manual Embedded fieldbus ...
Страница 584: ...2 238 ACH550 E Clipse Bypass User s Manual Diagnostics ...
Страница 608: ......
Страница 612: ...3 6 ACH550 UH User s Manual Table of contents ...
Страница 622: ...3 16 ACH550 PCR PDR User s Manual Installation ...
Страница 641: ......