Chapter 8 Basic Setting
GS1920v2 Series User’s Guide
88
Note: The PoE (Power over Ethernet) devices that supply or receive power and their
connected Ethernet cables must all be completely indoors.
The Po E- Disa b le d Me c ha nism fo r G S1920- 8HPv2
The GS1920-8HPv2 is a compact and fanless Switch capable of supplying Power over Ethernet (PoE).
Certain action will be taken when the temperature of the GS1920-8HPv2 reaches the temperature
thresholds. Please see the table below for how the mechanism works.
Note: The GS1920-8HPv2 will generate logs messages for the situations listed in the
Syste m Lo g
screen. They will also be sent to the syslog server.
8.8.1 The Po E Sta tus Sc re e n
To view the current amount of power that PDs are receiving from the Switch, click
Ba sic Se tting
>
Po E
Se tup
.
Fig ure 65
Basic Setting > PoE Setup
Table 18 Temperature and Action
TEMPERATURE
AC TIO N
74°C/165.2.°F
When the temperature of the GS1920-8HPv2 reaches this temperature threshold, the
SYS
LED will become steady red. See
Section 3.3 on page 40
for more information on the LEDs.
To cool down the GS1920-8HPv2, make sure there is enough clearance for ventilation. See
Chapter 2 on page 28
for more information. You can also relocate the GS1920-8HPv2 to a
cooler place.
79°C/174.2.°F
If the temperature keeps climbing and reaches this temperature threshold, PoE will be
turned off automatically.
Below 74°C/165.2.°F
PoE will be turned on again when the temperature drops and remains below this
temperature threshold for a 30-minute period.