SAFETY INFORMATION
Lattice Lightsheet 7
Notes on Setting up the System
ZEISS
04/2021 V_01
000000-2324-960
15
1.7
Notes on Setting up the System
Installation and commissioning of the Lattice Lightsheet 7 system must be performed by
authorized ZEISS service staff. The system should not be used prior to instruction by a ZEISS
representative.
The Lattice Lightsheet 7 systems are delivered in several crates.
The Lattice Lightsheet 7 system must be set up so as to ensure that the minimum clearance
between the wall and the rear of the system is no less than 0.5 m. This clearance is needed for
adjustment and maintenance operations.
The safe disconnection of the Lattice Lightsheet 7 system from mains supply is performed by
removing the power supply cables of the PSU and the multipoint power strips. The
Lattice Lightsheet 7 system must be set up and operated so that removing the connectors is not
difficult.
The liquid cooling system must be placed such that the air flow of the systems is not coupled.
The device must be placed securely on the table surface to prevent slipping and falling.
The system contains components with dangerous voltage. The system may be opened only by
authorized ZEISS service staff. Before opening a system component the power plug must be
disconnected.
Do not set up the unit in the proximity of heat sources such as radiators or direct sunlight. To
avoid heat build-ups, the ventilation louvers or slots on the microscope system must not be
covered up. Do not position the electronics parts in a closed container.
The system must not be set up in areas with potential danger by explosives.
The unit must be connected to a properly installed socket outlet with earthing contact by means
of the mains cables supplied. Continuity of PE connection must not be affected by the use of
extension leads.
Maintenance, repairs, modifications, removal or exchange of components, or other interference
with the equipment beyond the operations described in this manual may only be carried out by
the manufacturer ZEISS or by persons expressly authorized by ZEISS to do so.
This applies especially to the Lattice Lighsheet 7 system, incubator, stage, stage controller, lasers,
the PC system, the power supply units, cable connections and other system components.
Please note that the Lattice Lightsheet 7 system is a high-precision opto-electronic instrument.
Inexpert handling may easily impair its function or even damage it and will invalidate any claim
under warranty.
For reasons of laser safety, all ports must either be equipped with the corresponding device
(camera or safety plate) or covered with the counterpart of the laser safety kit provided. The user
is not allowed to remove any parts.