ST950S Plus+ Installation and Commissioning Manual
Figure 51. Above Ground Connection Detail
Table 35. Above Ground Detector Connection to Node
RAG Node Connection (PL2)
Heimdall Connection
1,2,or 3: IN1, IN2 or IN3 (XXX)
Detection (yellow or blue)
6,7or 8: 0V input common
Common (white)
9, 10 or 11: +24V
+24V (red)
20,21 or 22: 0V
OV (black)
For further information including mounting arrangements, please refer to the Heimdall Handbook (667/
HB/31900/000).
4.8.2. Adding Above Ground Detectors to Poles without Signal Heads
For above ground detectors that are installed on a pole without a signal head then a 3m cable kit with
inline connector, part Number 667/1/31960/104, must be ordered. Cable is connected to the AGD using
the inline connector and secured to the bracket including any excess cable length using cable ties
which are supplied in the kit.
If a Nearside is on the same pole then connect to the Nearside, see section 4.8.3.
Depending on application