ST950S Plus+ Installation and Commissioning Manual
3.18.3. Lamp Test Button
A button on the Manual Panel enables the indicators on the panel, including the Cabinet Alarm Lamp,
to be checked.
When the button is pressed, all LEDs on the Manual Panel should light. The lamp test is carried out
under software control, and although correct results indicate that the processor is communicating with
the Manual Panel, it does not guarantee that no faults are present.
3.18.4. Mode Select Buttons (Manual, VA, Fixed Time, Etc)
These keys select the required mode for the controller.
The controller can be configured so that manual mode is only available if a handset is plugged in. An
alternative configuration is such that manual mode may only be selected following a specific handset
command (see MND command).
3.18.5. Stage Select Buttons (All Red, 1 - 7)
With Manual mode selected (Manual LED lit), the keys ALL RED, 1 - 7 select the configured stage (or
combination of stages) provided the AWAITING COMMAND indicator is illuminated and a prohibited
stage move is not requested.
Page 77