ST950S Plus+ Installation and Commissioning Manual
Figure 81. 48V PSU DIN Rail Latch Release
The replacement PSU can then be clipped in place and the fitment of cables will be the reverse of the
operation described above.
10.4.5. Replacement of 24V PSU
Important:
Replacement of the 24V PSU – used to supply logic rails – will require the supply to the cabinet
to be switched off at the double pole master switch.
Once the controller cabinet has been shut down, the cables can be removed from the PSU. The PSU
will then need to be released from the DIN rail.
The replacement PSU can then be clicked into place, cables reinserted, and controller powered up.
10.4.6. Replacement of CPU Card
In case of failure, the CPU Card should be replaced. The Licence card and Heart of the controller (SD
card) should be moved to the new card to preserve the junction configuration and facilities.
Important:
Only replace a CPU card with a compatible variant: 667/1/46010/101
Page 148