ST950S Plus+ Installation and Commissioning Manual
Table 21. I/O Card LED Status (continued)
Comms Ac
tive LED (LP1)
Software Run
LED (LP2)
Watchdog LED (LP3)
State
Red
Green Flash
Off
Awaiting Start
Green Toggle on Re
ceipt of Message
Green Flash
Off
Communications Active
Off
Green / Red Alternating Off
Invalid Address
(As above depending
on state)
Red Flash
Off
Major Fault Detected
3.12.4. I/O Card Rotary Address Switch
This screwdriver-adjustable switch is located on the I/O card(s) as shown in
and is set up for the card address (before the controller is powered up) in
accordance with the appropriate Works Specification. The valid address range is 1 through 9. Address
0 is the default address switch position for spare cards.
Important:
The address range is shared with the Intelligent Detector Backplane cards and must be unique.
The address range is limited to 1 to 9. Addresses 10 and above are used by the CTBs. Due to
architecture of Plus
+
this is not expected to be a practical limitation.
3.12.5. Parts
24in 16 out panel mounted module - 667/1/46085/001
24in 4 out panel mounted module - 667/1/46085/002
3.13. CPU I/O Card
The CPU I/O card is designed to provide an ‘integrated’ I/O capability for ‘smaller’ controllers. The card
is mounted onto the CPU Card as shown below and provides 24 inputs and 4 changeover outputs.
All Inputs and outputs are TOPAS 2523 compliant. LEDs and GSPI ports are as described above for
standard IO cards and the CPU IO card has a fixed address: 1.
May flash so fast that it looks like Green Steady.
Page 60