ST950S Plus+ Installation and Commissioning Manual
Other applications and features of the equipment may require access to additional services either on
the internet or on a local network. The documentation for these applications and features record these
requirements.
6.9.9.2. Licence Card for STRATOS Connection
A Licence Smartcard version 2 is required to support connections to Stratos. The version of the Licence
Smartcard fitted can be checked on the System – Settings – Comms – Stratos configuration web page.
The UTMC OTU licence controls whether or not connection to Stratos is supported – see section
6.9.9.3. Ethernet Configuration for STRATOS
Ethernet can be fully configured manually if required but configuration can be minimised by using
DHCP.
To connect the equipment to Stratos perform the following:
1. Set the date and time (
System - Settings - System Date & Time - Set System Date & Time
web
page).
2. On the
System - Settings - Comms – Stratos
web page:
a. Set the Tenant Pass Phrase.
b. Set the Site Location.
c. Set the Site Name.
3. Set the profile to Stratos (
System – Settings
web page).
4. Check that Ethernet is suitably configured (
System - Settings - Comms - DSL/Fibre
web page).
Using the Stratos profile sets this to DHCP. If this not suitable then configure as required.
5. Connect the Ethernet port to a network which has connectivity to the services described above.
6.9.9.4. Setting the Site Name, Site Location & Tenant Pass Phrase
These items are set on the System – Settings – Comms – Stratos configuration web page.
Specifying a Tenant Pass Phrase prior to initial connection allows the equipment to be automatically
allocated to the specified tenant on initial connection to Stratos. If the Tenant Pass Phrase is not
specified at the time of initial connection then the equipment will be allocated to the Yunex Traffic
Support team who can then make the allocation when required based on the outstation name, unique
site id and destination tenant. This item has no effect after initial connection to Stratos.
6.9.9.5. Setting the Profile to STRATOS
Equipment is supplied configured for use in non-Stratos systems. To configure it for use with Stratos,
visit the System – Settings configuration web page and set the
Profile
to
Stratos
.