<2. Handling Cautions>
2-15
IM 01C25W05-01EN
2.9.4 Name Plate
FF1
EXPLOSIONPROOF CL I, DIV 1, GPS B,C & D
DUST-IGNITIONPROOF CL II/III, DIV 1, GPS E,F & G
TEMP. CLASS T6 TYPE 4X
AMB. TEMP. -40 TO 60ºC
OPEN CIRCUIT BEFORE REMOVING COVER.
FACTORY SEALED, CONDUIT SEAL NOT REQUIRED.
INSTALL IN ACCORDANCE WITH THE USER'S MANUAL
IM 01C25 or IM 01C26.
AFTER DE-ENERGIZING, DELAY 10 MINUTES BEFORE OPENING.
POTENTIAL ELECTROSTATIC CHARGING HAZARD - SEE THE USER’S MANUAL.
WHEN THE AMBIENT TEMP. ≥ 65
º
C
, USE THE HEAT- RESISTING CABLE & CABLE GLAND ≥ 90
º
C
.
No . KEMA 07ATEX0109 X
Ex db
II
C T6 . . .T4 Gb, Ex tb
III
C T85º
C
Db
TEMP CLASS
T6 T5 T4
PROCESS TEMP. (Tp.) -50 TO 85 100 120º
C
Tamb. (for GAS)
-50 TO 75 80
75º
C
T85º
C
(Tamb. : -30 (-15) TO 75º
C
, Tp. : -30 (-15) TO 85º
C
) (for DUST)
SEE USER’S MANUAL
ENCLOSURE: IP66/IP67
FS14-P
IS CL I/II/III DIV 1 GP ABCDEFG T4
CL I ZN 0 AEx ia IIC T 4
Supply/Output : Ui=30V, Ii=200mA, Pi=0.9W, Ci=27.6nF, Li=0mH
Communication : Uo=8.2V, Io=160mA, Po=0.3W, Co=7.6
µF, Lo=1mH
NI CL I/II D I V 2 G P A B C D F G C L III DIV I
CL I ZN 2 GP IIC T 4
Supply/Output : Ui=30V, Ci=27.6nF, Li=0mH
Communication : Uo=8.2V, Io=160mA, Po=0.3W, Co=7.6
µF, Lo=1mH
-50 ≤
Ta
≤
60ºC TYPE 4X, IP66/IP67
SUBSTITUTION OF COMPONENTS MAY
IMPAIR INTRINSIC SAFETY
INSTALL IN ACCORDANCE WITH IIE028-A101
POTENTIAL ELECTROSTATIC
CHARGING HAZARD-
SEE USER'S MANUAL
FS14-S
POTENTIAL ELECTROSTATIC
CHARGING HAZARD-
SEE USER'S MANUAL
IS CL I/II/III DIV 1 GP ABCDEFG T4
CL I ZN 0 AEx ia IIC T 4
NI CL I/II D I V 2 G P A B C D F G C L III DIV I
CL I ZN 2 GP IIC T 4
-50
≤
Ta
≤
60ºC TYPE 4X, IP66/IP67
Ui=8.2V, Ii=200mA, Pi=0.4W, Ci=6µF, Li=0mH
SUBSTITUTION OF COMPONENTS MAY
IMPAIR INTRINSIC SAFETY
INSTALL IN ACCORDANCE WITH IIE028-A101
KS24-P
No. FM16ATEX0014X
Ex ia IIC T4 Ga
-50
≤
Ta
≤
60ºC IP66/IP67
MAX PROCESS TEMP. 120ºC
Supply/Output
Ui=30V, Ii=200mA, Pi=0.9W, Ci=27.6nF, Li=0mH
Communication
Uo=8.2V, Io=160mA, Po=0.3W, Co=7.6µF, Lo=1mH
POTENTIAL ELECTROSTATIC
CHARGING HAZARD-
SEE USER'S MANUAL
KS24-S
No. FM16ATEX0014X
Ex ia IC T4 Ga
-50
≤
Ta
≤
60ºC IP66/IP67
MAX PROCESS TEMP. 120ºC
Ui=8.2V, Ii=200mA, Pi=0.4W, Ci=6µF, Li=0mH
POTENTIAL ELECTROSTATIC
CHARGING HAZARD-
SEE USER'S MANUAL
SS24-P
No. IECEx FMG 16.0013X
Ex ia IIC T4 Ga
-50
≤
Ta
≤
60ºC IP66/IP67
MAX PROCESS TEMP. 120ºC
Supply/Output
Ui=30V, Ii=200mA, Pi=0.9W, Ci=27.6nF, Li=0mH
Communication
Uo=8.2V, Io=160mA, Po=0.3W, Co=7.6µF, Lo=1mH
POTENTIAL ELECTROSTATIC
CHARGING HAZARD-
SEE USER'S MANUAL
SS24-S
No. IECEx FMG 16.0013X
Ex ia IIC T4 Ga
-50
≤
Ta
≤
60ºC IP66/IP67
MAX PROCESS TEMP. 120ºC
Ui=8.2V, Ii=200mA, Pi=0.4W, Ci=6µF, Li=0mH
POTENTIAL ELECTROSTATIC
CHARGING HAZARD-
SEE USER'S MANUAL
FM flameproof type optional code /FF1
Name plate
Tag plate
ATEX flameproof type optional code /KF22
IECEx flameproof type optional code /SF2
FM Intrinsically safe type optional code /FS14
[EJX****-P, EJA****-P]
[EJX****-S, EJA****-S]
ATEX intrinsically safe type optional code /KS24
[EJX****-P, EJA****-P]
[EJX****-S, EJA****-S]
IECEx Intrinsic safety type optional code /SS24
[EJX****-P, EJA****-P]
[EJX****-S, EJA****-S]
F0208.ai
MODEL: Specified model code.
STYLE: Style code.
SUFFIX: Specified suffix code.
SUPPLY: Supply voltage.
OUTPUT: Output signal.
MWP: Maximum working pressure.
CAL RNG: Specified calibration range.
NO.: Serial number and year of production
*1
.
TOKYO 180-8750 JAPAN:
The manufacturer name and the address
*2
.
*1: The first digit in the three numbers next to the nine
letters of the serial number appearing after “NO.”
on the nameplate indicates the year of production.
The following is an example of a serial number for a
product that was produced in 2010:
The year 2010
91K819857 032
*2: “180-8750” is a zip code which represents the
following address.
2-9-32 Nakacho, Musashino-shi, Tokyo Japan
*3: The identification number of Notified Body.