10.1 Troubleshooting
10-5
A.CF2
Fully-closed Serial
Converter Unit
Communications Error
(Timer Stopped)
Communication of fully-closed serial converter unit is faulty.
DB stop
N/A
H
A.d00
Position Error Pulse
Overflow
Position error pulse exceeded parameter (Pn520).
DB stop
Available
A.d01
Position Error Pulse
Overflow Alarm
at Servo ON
When the servo turns ON, the position error pulses exceeded
the parameter setting (Pn526).
DB stop
Available
A.d02
Position Error Pulse
Overflow Alarm by Speed
Limit at Servo ON
If the servo turns ON with position error pulses accumulated,
the speed is limited by Pn529. In this state, the reference
pulse was input without resetting the speed limit, and the
position error pulses exceeds the value set for the parameter
Pn520.
Zero speed
stop
Available
A.d10
Motor-Load Position
Error Pulse Overflow
Position error pulse between motor and load is too large.
Zero speed
stop
Available
A.E00
COM Alarm 0
SERVOPACK “COM error 0.”
Zero speed
stop
Available
A.E01
COM Alarm 1
SERVOPACK “COM error 1.”
Zero speed
stop
Available
A.E02
COM Alarm 2
SERVOPACK “COM error 2.”
Zero speed
stop
Available
A.E07
COM Alarm 7
SERVOPACK “COM error 7.”
Zero speed
stop
N/A
A.E40
MECHATROLINK II
Transmission Cycle
Setting Error
Transmission cycle setting of MECHATROLINK II is
incorrect.
Zero speed
stop
Available
A.E50
MECHATROLINK II
Synchronization Error
Synchronization error during MECHATROLINK II
communications.
Zero speed
stop
Available
A.E51
MECHATOLINK II
Synchronization Failed
Synchronization error during MECHATROLINK II
communications.
A.E60
MECHATROLINK II
Communications Error
Continuous communications error during
MECHATROLINK II communications.
Zero speed
stop
Available
A.E61
MECHATROLINK II
Transmission Cycle Error
Transmission cycle error during MECHATROLINK II
communications.
Zero speed
stop
Available
A.EA0
DRV Alarm 0
SERVOPACK “DRV error 0.”
DB stop
N/A
A.EA1
DRV Alarm 1
SERVOPACK “DRV error 1.”
DB stop
N/A
A.EA2
DRV Alarm 2
SERVOPACK “DRV error 2.”
Zero speed
stop
Available
A.ED0
Internal Command Error
Command error in the SERVOPACK.
Zero speed
stop
Available
A.F10
Power Line Open Phase
One phase is not connected in the main power supply.
Zero speed
stop
Available
CPF00
Digital Operator
Transmission Error
Digital operator (JUSP-OP05A) fails to communicate with
SERVOPACK (e.g., CPU error).
−
N/A
CPF01
−
N/A
A.
− −
Not an error
Normal operation status
−
−
L
Table 10.1 Alarm Display Table (Cont’d)
Alarm
Display
Alarm Name
Meaning
Servomo-
tor Stop
Method
Alarm
Reset
Servo
Alarm
(ALM)
Output
Summary of Contents for SGDS Sigma III Series
Page 3: ...SGDS Sigma III Servo Amplifier User Manual for Mechatrolink II Communications...
Page 21: ......
Page 59: ...2 System Selection 2 5 4 Regenerative Resistors 2 28...
Page 68: ...3 3 SERVOPACK Internal Block Diagrams 3 9 3 3 3 Three phase 200 V 1 0 kW...
Page 82: ...3 7 Dimensional Drawings of Base mounted SERVOPACK Model SGDS 12A 12A 3 23 Three phase 1 5kW...
Page 133: ...5 Wiring 5 7 2 Connecting Externally Regenerative Resistors 5 28...
Page 229: ...7 Operation 7 7 4 Absolute Encoder Home Position Offset 7 38...