6 MECHATROLINK II Communications
6.4.9 Status Monitoring (SMON: 30H)
6-48
6.4.9 Status Monitoring (SMON: 30H)
Byte
SMON
Description
Command
Response
Processing
classifications
Data communica-
tions command
group
Processing time
Within
communications
cycle
17
30H
30H
• Reads the monitoring information specified in SEL_MON3/4. This command
has the same function as the main command SMON.
• This command can be used only with the following main commands:
NOP, ID-RD, HOLD, LTMOD-ON/OFF, SMON, SV-ON/OFF,
INTERPOLATE, POSING, FEED, LATCH, EX-POSING, ZRET, VERCTRL,
TRQCTRL
18
Substatus
19
SEL_MON3/4
SEL_MON3/4
20
MONITOR3
21
22
23
24
MONITOR4
25
26
27
28
29