6 MECHATROLINK II Communications
6.5.4 Monitor Selection and Monitor Information Field Specifications: SEL_MON1/2/3/4, MONITOR1/2/3/4
6-52
6.5.4 Monitor Selection and Monitor Information Field Specifications:
SEL_MON1/2/3/4, MONITOR1/2/3/4
The monitor selection and monitor information field specifications (SEL_MON1/2/3/4, MONITOR1/2/3/4) can
be designated using the following main commands:
SV_ON, SV_OFF, HOLD, INTERPOLATE, POSING, FEED, LATCH, EX_POSING, ZRET, VCELCTRL,
TRQCTRL, SMON, SENS_ON, SENS_OFF, BRK_ON, BRK_OFF, LTMOD-ON, LTMOD-OFF
The monitor selection and monitor information field is used to select the Servo monitor information and monitor
it, with the thirteenth byte of the above main commands, or the nineteenth byte reserved area of the
subcommands.
• SEL_MON1/2/3/4 Field
• MONITOR1/2/3/4 Monitor Codes
D11
NEAR
Positioning proximity
0
Out of positioning proximity
range
Position
control mode
1
Within positioning proximity
range
V_LIM
Speed limit
0
Speed limit not detected
Torque
control mode
1
Speed limit detected
D12
P_SOT
Forward software limit
0
Out of range
1
Within range
D13
N_SOT
Reverse software limit
0
Out of range
1
Within range
D14
Reserved
D15
Reserved
(cont’d)
Bit
Name
Description
Set
Value
Details
Control
Mode
D7
D6
D5
D4
D3
D2
D1
D0
SEL_MON2
SEL_MON1
D7
D6
D5
D4
D3
D2
D1
D0
SEL_MON4
SEL_MON3
Monitor
Codes*
Name
Description
Unit
0
POS
Reference position in the reference coordi-
nate system (position after reference filter
procedure)
Reference units
1
MPOS
Reference position in the mechanical coordi-
nate system
Reference units
2
PERR
Position error
Reference units
3
APOS
Feedback position in the mechanical coordi-
nate system
Reference units
4
LPOS
Feedback latch position in the mechanical
coordinate system
Reference units
5
IPOS
Reference position in the reference coordi-
nate system (position before reference filter
procedure)
Reference units
6
TPOS
Target position in the reference coordinate
system
Reference units
Summary of Contents for SGDS Sigma III Series
Page 3: ...SGDS Sigma III Servo Amplifier User Manual for Mechatrolink II Communications...
Page 21: ......
Page 59: ...2 System Selection 2 5 4 Regenerative Resistors 2 28...
Page 68: ...3 3 SERVOPACK Internal Block Diagrams 3 9 3 3 3 Three phase 200 V 1 0 kW...
Page 82: ...3 7 Dimensional Drawings of Base mounted SERVOPACK Model SGDS 12A 12A 3 23 Three phase 1 5kW...
Page 133: ...5 Wiring 5 7 2 Connecting Externally Regenerative Resistors 5 28...
Page 229: ...7 Operation 7 7 4 Absolute Encoder Home Position Offset 7 38...