8 Adjustments
8.5.4 Speed Loop Gain
8-22
8.5.4 Speed Loop Gain
8.5.5 Speed Loop Integral Time Constant
(1) PI Control (Pn10B.1=0)
(2) IP Control (Pn10B.1=1)
In cases where the load moment of inertia is large and there are vibration elements in the mechanical system,
vibrations may occur in the equipment unless Pn101 is set to a value somewhat higher than the estimated set
value derived from the equation above.
Selecting the Speed Loop Control Method (PI Control or I-P Control)
Generally, I-P control is more effective in high-speed positioning or high-speed/precision manufacturing applications. The
position loop gain is lower than it would be in PI control, so shorter positioning times and smaller arc radii can be
achieved. On the other hand, PI control is generally used when switching to P control fairly often with a mode switch or
other method.
Pn100
Speed Loop Gain (Kv)
Setting Range
Setting Unit
Factory Setting
Setting Validation
1.0 to 2,000.0 Hz
0.1 Hz
40.0 Hz
Immediately
This parameter determines the responsiveness of the speed loop. The responsiveness increases and the positioning time
decreases when the position loop gain is set to a higher value. If the speed loop’s responsiveness is too low, it will delay the
outer position loop and cause overshooting and vibration of the speed reference. The SERVOPACK will be most stable and
responsive when the speed loop gain is set as high as possible within the range that does not cause vibration in the
mechanical system. The value of speed loop gain is the same as the set value of Pn100 if Pn103 (The moment of inertia
ratio) has been set correctly.
Speed
Position
Pn103
Moment of Inertia Ratio
Setting Range
Setting Unit
Factory Setting
Setting Validation
0% to 20,000%
1%
0%
Immediately
The factory setting is Pn103=0. Before adjusting the servo, determine the moment of inertia ratio with the equation above
and set parameter Pn103.
Pn101
Speed Loop Integral Time Constant (Ti)
Setting Range
Setting Unit
Factory Setting
Setting Validation
0.15 to 512.00 ms
0.01 ms
20.00 ms
Immediately
The speed loop has an integral element so that the speed loop can respond to minute inputs. This integral element causes a
delay in the SERVOPACK. If the time constant is set too long, overshooting will occur, which results in a longer
positioning settling times or response decreases.
The estimated set value for Pn101 depends on the speed loop control method with Pn10B.1, as shown below.
Speed
Position
Torque
Pn103 set value =
Motor axis conversion load moment of inertia (J
L
)
×
100(
%
)
Servomotor rotor moment of inertia (J
M
)
Speed
Position
Example: Pn100 = 40.0 (Hz);
Example: Pn100 = 40.0 (Hz);
Pn101 set value =
2
π ×
Pn100 set value
4000
Pn101 15.92 (ms) =
2
π ×
40.0 (Hz)
4000
Pn101 set value =
2
π ×
Pn100 set value
2000
Pn101 7.96 (ms) =
2
π ×
40.0 (Hz)
2000
INFO
Summary of Contents for SGDS Sigma III Series
Page 3: ...SGDS Sigma III Servo Amplifier User Manual for Mechatrolink II Communications...
Page 21: ......
Page 59: ...2 System Selection 2 5 4 Regenerative Resistors 2 28...
Page 68: ...3 3 SERVOPACK Internal Block Diagrams 3 9 3 3 3 Three phase 200 V 1 0 kW...
Page 82: ...3 7 Dimensional Drawings of Base mounted SERVOPACK Model SGDS 12A 12A 3 23 Three phase 1 5kW...
Page 133: ...5 Wiring 5 7 2 Connecting Externally Regenerative Resistors 5 28...
Page 229: ...7 Operation 7 7 4 Absolute Encoder Home Position Offset 7 38...