6.3.19 Request Latch Mode (LTMOD_ON: 28H)
• Related Parameters
Byte
LTMOD_ON
Description
Command
Response
1
28H
28H
Processing
classifications
Control com-
mand group
Synchronization
classifications
Asynchronous
2
LT_SGN
ALARM
Processing time
Within communi-
cations cycle
Subcommand
Can be used
3
STATUS
• Sets the modal latch mode. If a latch signal is input during modal latch mode,
position latching will be performed.
• Can be used during phases 2 and 3.
• During phase 1 Command warning 1 (A.95A) will occur and the command
will be ignored..
• A latch signal can be selected using LT_SGN. Refer to 6.5.1 Latch Signal
Field Specifications (LT_SGN).
• Use CMDRDY = 1 to confirm that the Request Latch Mode command has
been received.
• It takes 500
µ
s max. for the Request Latch Mode command to start.
• Confirm that L_CMP is 1 in STATUS at the completion of latching.
- When there is monitor data such as SMON or POSING appended to the
command response, LPOS is forcefully returned to MONITOR2 for one
communication cycle.
- When there is no monitor data such as PRM_RD or ALM_RD appended to
the command response, confirm that L_CMP is 1 in STATUS, then use a
command that has monitor data such as SMON in the response and select
LPOS to confirm.
• Once the latch operation has been performed, it will not be performed again
even if a latch signal is input. Send a new LTMOD_ON command.
• Interference with another latch mode command
- During the execution of a command such as LATCH, ZRET, EX_POSING,
or SVCTRL, the LTMOD_ON command cannot be used. If this command is
used during the execution of these commands, the warning Command
warning 4 (A.95D) will occur.
4
5
MONITOR1
6
7
8
9
MONITOR2
10
11
12
13
SEL_MON 1/2
SEL_MON 1/2
14
IO_MON
15
16
WDT
RWDT
17
For
subcommands.
Refer to
6.4
Subcommands
.
For
subcommands.
Refer to
6.4
Subcommands
.
18
19
20
21
22
23
24
25
26
27
28
29
Pn No.
Description
Pn511
Input Signal Selections 5
Pn820
Latching Area Upper Limit
Pn822
Latching Area Lower Limit
Summary of Contents for SGDS Sigma III Series
Page 3: ...SGDS Sigma III Servo Amplifier User Manual for Mechatrolink II Communications...
Page 21: ......
Page 59: ...2 System Selection 2 5 4 Regenerative Resistors 2 28...
Page 68: ...3 3 SERVOPACK Internal Block Diagrams 3 9 3 3 3 Three phase 200 V 1 0 kW...
Page 82: ...3 7 Dimensional Drawings of Base mounted SERVOPACK Model SGDS 12A 12A 3 23 Three phase 1 5kW...
Page 133: ...5 Wiring 5 7 2 Connecting Externally Regenerative Resistors 5 28...
Page 229: ...7 Operation 7 7 4 Absolute Encoder Home Position Offset 7 38...