6 MECHATROLINK II Communications
6.5.2 Option Field Specifications: OPTION
6-50
6.5.2 Option Field Specifications: OPTION
The option field specifications (OPTION) can be designated using the following main commands:
SV_ON, HOLD, INTERPOLATE, POSING, FEED, LATCH, EX_POSING, ZRET, VELCTRL, TRQCTRL
The option field is used to add motion command functions, with the third to fourth byte reserved area of the
above main commands.
Refer to the following table for details on bit allocation.
• Option Field
D7
D6
D5
D4
D3
D2
D1
D0
0
0
0
ACCFIL
0
0
0
D15
D14
D13
D12
D11
D10
D9
D8
N-CL
P-CL
P-PI-CLR
V-PPI
0
0
G-SEL
Bit
Name
Description
Set
Value
Details
D0
0
D1
0
D2
0
D3
ACCFIL
Acceleration/deceleration filter
Note: Never change acceleration/deceleration filter
during output (when DEN of STATUS is set to 0).
0
No acceleration/deceleration
filter
1
Exponential acceleration/
deceleration
D4
2
S-curve
acceleration/deceleration
3
Do not set.
D5
0
D6
0
D7
0
D8
G-SEL
Gain switching
0
First gain
1
Second gain
D9
2
Third gain
3
Fourth gain
D10
0
D11
0
D12
PPI
Speed loop P/PI control
0
PI control
1
P control
D13
P_PI_CL
R
Position loop position Integral clear
0
Clear.
1
Does not clear.
D14
P-CL
Forward torque limit
0
Controls torque.
1
Does not control torque.
D15
N-CL
Reverse torque limit
0
Controls torque.
1
Does not control torque.
Summary of Contents for SGDS Sigma III Series
Page 3: ...SGDS Sigma III Servo Amplifier User Manual for Mechatrolink II Communications...
Page 21: ......
Page 59: ...2 System Selection 2 5 4 Regenerative Resistors 2 28...
Page 68: ...3 3 SERVOPACK Internal Block Diagrams 3 9 3 3 3 Three phase 200 V 1 0 kW...
Page 82: ...3 7 Dimensional Drawings of Base mounted SERVOPACK Model SGDS 12A 12A 3 23 Three phase 1 5kW...
Page 133: ...5 Wiring 5 7 2 Connecting Externally Regenerative Resistors 5 28...
Page 229: ...7 Operation 7 7 4 Absolute Encoder Home Position Offset 7 38...