2.1 Ratings and Specifications
2.1.3 Specifications
2-7
2
Selecting a SER
VOP
ACK
*1.
If you combine a
Σ
-7-Series SERVOPACK with a
Σ
-V-Series Option Module, the surrounding air temperature
specification of the
Σ
-V-Series SERVOPACKs must be used, i.e., 0°C to 55°C. Also, the applicable surrounding
range cannot be increased by derating.
*2.
The coefficient of speed fluctuation for load fluctuation is defined as follows:
*3.
Usable only with SGD7S-210D, -260D, -280D, -370D SERVOPACKs.
*4.
The /DBON signal can be used as positive logic.
*5.
The SGD7S-210D, -260D, -280D, and -370D do not have a dynamic brake (DB). If a dynamic brake is neces-
sary, create an external dynamic brake circuit.
Refer to the following chapter for details on the dynamic brake.
Chapter 5 Wiring and Settings for the Dynamic Brake
*6.
Always perform risk assessment for the system and confirm that the safety requirements are met.
Safety
Functions
Inputs
/HWBB1 and /HWBB2: Base block signals for Power Modules
Output
EDM1: Monitors the status of built-in safety circuit (fixed output).
Applicable
Standards
*6
ISO13849-1 PLe (category 3), IEC61508 SIL3
Applicable Option Modules
Fully-closed Modules
Continued from previous page.
Item
Specification
×
100%
Coefficient of speed fluctuation =
No-load motor speed - Total-load motor speed
Rated motor speed