17.4 Parameter Recording Table
17-46
Pn306
(2306h)
0
Soft Start Deceleration
Time
Immediately
Pn308
(2308h)
0
Speed Feedback Filter
Time Constant
Immediately
Pn30A
(230Ah)
0
Deceleration Time for Servo
OFF and Forced Stops
Immediately
Pn30C
(230Ch)
0
Speed Feedforward Aver-
age Movement Time
Immediately
Pn310
(2310h)
0000h
Vibration Detection Selec-
tions
Immediately
Pn311
(2311h)
100
Vibration Detection Sensi-
tivity
Immediately
Pn312
(2312h)
50
Vibration Detection Level
Immediately
Pn316
(2316h)
10000
Maximum Motor Speed
After restart
Pn324
(2324h)
300
Moment of Inertia Calcula-
tion Starting Level
Immediately
Pn383
(2383h)
50
Jogging Speed
Immediately
Pn384
(2384h)
10
Vibration Detection Level
Immediately
Pn385
(2385h)
50
Maximum Motor Speed
After restart
Pn401
(2401h)
100
First Stage First Torque
Reference Filter Time Con-
stant
Immediately
Pn402
(2402h)
800
Forward Torque Limit
Immediately
Pn403
(2403h)
800
Reverse Torque Limit
Immediately
Pn404
(2404h)
100
Forward External Torque
Limit
Immediately
Pn405
(2405h)
100
Reverse External Torque
Limit
Immediately
Pn406
(2406h)
800
Emergency Stop Torque
Immediately
Pn407
(2407h)
10000
Speed Limit during Torque
Control
Immediately
Pn408
(2408h)
0000h
Torque-Related Function
Selections
*
Pn409
(2409h)
5000
First Stage Notch Filter Fre-
quency
Immediately
Pn40A
(240Ah)
70
First Stage Notch Filter Q
Value
Immediately
Pn40B
(240Bh)
0
First Stage Notch Filter
Depth
Immediately
Pn40C
(240Ch)
5000
Second Stage Notch Filter
Frequency
Immediately
Pn40D
(240Dh)
70
Second Stage Notch Filter
Q Value
Immediately
Pn40E
(240Eh)
0
Second Stage Notch Filter
Depth
Immediately
Continued on next page.
Continued from previous page.
Parameter
No.
Default
Setting
Name
When
Enabled