9.11 Speed Ripple Compensation
9.11.3 Setting Parameters
9-63
9
T
uning
10.
Click the
Forward
Button or the
Reverse
Button.
Verification operation is started.
The motor will rotate at the preset jogging speed while you hold down the
Forward
or
Reverse
But-
ton.
The waveform with speed ripple compensation applied to it will be displayed.
11.
If the verification results are OK, click the
Finish
Button.
This concludes the setup for speed ripple compensation.
9.11.3
Setting Parameters
The function is enabled when you perform the operating procedure on
page 9-60. To cancel speed ripple compensation, use Pn423 = n.
0 (Disable speed ripple
compensation) to disable it.
If you enable speed ripple compensation, a compensation reference will be applied to reduce
ripple even when stopped at a 0 speed reference. In speed control mode, this may result in the
motor moving slightly. To prevent this, set Pn423 = n.
X
(Speed Ripple Compensation
Selections) and Pn427 or Pn49F (Speed Ripple Compensation Enable Speed).
•
For Rotary Servomotors
•
For Linear Servomotors
To discard the setup results, click the
Reset
Button.
Information
Parameter
Description
When
Enabled
Classifi-
cation
Pn423
(2423h)
n.
0
(default setting)
Disable speed ripple compensation.
After
restart
Setup
n.
1
Enable speed ripple compensation.
Parameter
Description
When
Enabled
Classifi-
cation
Pn423
(2423h)
n.
0
(default setting)
Speed reference
After
restart
Setup
n.
1
Motor Speed
Pn427
(2427h)
Speed Ripple Compensation Enable Speed
Setting Range
Setting Unit
Default Setting
When Enabled
Classification
0 to 10,000
1 min
-1
0
Immediately
Tuning
Pn49F
(249Fh)
Speed Ripple Compensation Enable Speed
Setting Range
Setting Unit
Default Setting
When Enabled
Classification
0 to 10,000
1 mm/s
0
Immediately
Tuning
Speed
Position
Torque
Speed
Position
Torque