5.3 SERVOPACK Models without a Built-In Dynamic Brake
5.3.1 Using the Dynamic Brake
5-10
5.3
SERVOPACK Models without a Built-In Dynamic Brake
This section describes how to use the SERVOPACKs (SGD7S-210D to 370D) that are not
equipped with a built-in dynamic brake.
5.3.1
Using the Dynamic Brake
The SGD7S-210D to 370D are not equipped with a built-in dynamic brake.
When using the SGD7S-210D to 370D, set up the SERVOPACK according to the following
flowchart.
With the SGD7S-210D to 370D, A.042 (Parameter Combination Error) will always occur when
the power supply is first turned ON. This alarm occurs because the settings for the dynamic
brake have not been configured. After you set the parameters according to the following flow-
chart, the A.042 alarm will be reset when the power supply is turned OFF and ON again.
A.042 (Parameter Combination Error) occurs.
Using the dynamic
brake?
No
Yes
Select the Dynamic Brake Resistor.
Set the motor stopping method
when not using the dynamic
brake. (Pn000 = n.
X)
Select the Magnetic Contactor and
Relay for the dynamic brake.
Preparations completed when not
using the dynamic brake.
Wire the dynamic brake circuit.
Set signals for the dynamic brake.
Set the motor stopping method.
(Pn001 = n.
X)
Set the allowable energy consumption and resis-
tance of the Dynamic Brake Resistor. (Pn601, Pn604)
Preparations completed when