TRBL
SHTG
Troubleshooting
9-15
6C13G11
Replace the engine stop lan-
yard switch.
Yes
No
Is there continuity?
Check the resistance of each
ignition coil.
Yes
Repair or replace the spark plug
wire.
No
Good condition?
Check the ECM output peak
voltage.
Yes
Replace the ignition coils.
No
Check the resistance of each
spark plug wire and check the
spark plug caps for salt buildup.
Good condition?